Power distribution cables, Models 988, 88E all-flash

These tables show the point-to-point connections for power distribution unit (PDU) cables in Models 988, 88E.

Figure 1. Model 984, 985, 986, 988 base rack locations
Note: Rack-1 shown. PJAs E51, E52, E53, and E54 can also be present in Rack-2. DC-UPS locations are similar for models 98x and 8xE.
Model 984, 985, 986, 988 base rack locations
Figure 2. Locations for power distribution unit (PDU) connectorsLocations for power distribution unit (PDU) connectors
Figure 3. Power junction assembly (PJA) locations (models 984, 985, 986, 988)
Power junction assembly (PJA) locations (models 984, 985, 986, 988)
Figure 4. Direct power junction assembly (direct PJA) locations (models 984, 84E, 985, 85E, 986, 86E, 988, 88E)
Direct power junction assembly (direct PJA) locations (models 984, 84E, 985, 85E, 986, 86E, 988, 88E)
Table 1, Table 2, and Table 3 show power cables between the power distribution units (PDUs) and the DC uninterruptible power supplies (DC-UPSs).
Table 4, Table 5, and Table 6 show power cables between the PDUs and the CEC enclosure, I/O enclosure, and storage enclosure power supplies.

Table 7 and Table 8 show power cables between the PJAs, the I/O enclosures, and the HMC, monitor, and Ethernet switches.

Table 9, Table 10, Table 11, and Table 12 show power cables between the PJAs and microbays.
Table 1. PDU-to-DC-UPS cabling - Rack 1 (Models 988, 88E)
PDU port Connects to Connection description P/N FRU/PN PDU group
Note: For more information on the connects to locations in this table, refer to Rack power and cooling location codes (Models 98x) (not 983).
E21-P1 E1-J1-1 DC-UPS E1 (left), DDM source 1     Green
E21-P2 E1-J2-1 DC-UPS E1 (left), main source 1     Green
E22-P1 E2-J1-1 DC-UPS E2 (right), DDM source 1     Yellow
E22-P2 E2-J2-1 DC-UPS E2 (right), main source 1     Yellow
E23-P1 E1-J2-2 DC-UPS E1 (left), main source 2     Green
E23-P2 E1-J2-3 DC-UPS E1 (left), main source 3     Green
E24-P1 E2-J2-2 DC-UPS E2 (right), main source 2     Yellow
E24-P2 E2-J2-3 DC-UPS E2 (right), main source 3     Yellow
Table 2. PDU-to-DC-UPS cabling - Rack 2 (Models 988, 88E)
PDU port Connects to Connection description P/N FRU/PN PDU group
Note: For more information on the connects to locations in this table, refer to Rack power and cooling location codes (Models 98x) (not 983).
E21-P1 E1-J1-1 DC-UPS E1 (left), DDM source 1     Green
E21-P2 E1-J1-2 DC-UPS E1 (left), DDM source 2     Green
E22-P1 E2-J1-1 DC-UPS E2 (right), DDM source 1     Yellow
E22-P2 E2-J1-2 DC-UPS E2 (right), DDM source 2     Yellow
E23-P1 E1-J2-2 DC-UPS E1 (left), main source 2     Green
E23-P2 E1-J2-3 DC-UPS E1 (left), main source 3     Green
E24-P1 E2-J2-2 DC-UPS E2 (right), main source 2     Yellow
E24-P2 E2-J2-3 DC-UPS E2 (right), main source 3     Yellow
Table 3. PDU-to-DC-UPS cabling - Rack 3 (Models 988, 88E)
PDU port Connects to Connection description P/N FRU/PN PDU group
Note: For more information on the connects to locations in this table, refer to Rack power and cooling location codes (Models 98x) (not 983).
E21-P1 E1-J1-1 DC-UPS E1 (left), DDM source 1     Green
E21-P2 E1-J2-1 DC-UPS E1 (left), main source 1     Green
E22-P1 E2-J1-1 DC-UPS E2 (right), DDM source 1     Yellow
E22-P2 E2-J2-1 DC-UPS E2 (right), main source 1     Yellow
E23-P1 E1-J1-2 DC-UPS E1 (left), DDM source 2     Green
E23-P2 E1-J1-3 DC-UPS E1 (left), DDM source 3     Green
E24-P1 E2-J1-2 DC-UPS E2 (right), DDM source 2     Yellow
E24-P2 E2-J1-3 DC-UPS E2 (right), DDM source 3     Yellow
Table 4. PDU-to-CEC, I/O, and storage enclosure cabling - Rack 1 (Models 988, 88E)
PDU port Connects to Connection description P/N FRU/PN PDU group
PDU E21 (upper half)
E21-J1 F01-E1 Storage enclosure F01 PSU E1 (left)     Green
E21-J2 F02-E1 Storage enclosure F02 PSU E1 (left)     Green
E21-J3 F03-E1 Storage enclosure F03 PSU E1 (left)     Green
E21-J4 F04-E1 Storage enclosure F04 PSU E1 (left)     Green
E21-J5 F05-E1 Storage enclosure F05 PSU E1 (left)     Green
E21-J6 F06-E1 Storage enclosure F06 PSU E1 (left)     Green
PDU E21 (lower half)
E21-J7   Not used     Green
E21-J8   Not used     Green
E21-J9   Not used     Green
E21-J10   Not used     Green
E21-J11 F07-E1 Storage enclosure F07 PSU E1 (left)     Green
E21-J12 F08-E1 Storage enclosure F08 PSU E1 (left)     Green
PDU E22 (upper half)
E22-J1 F01-E2 Storage enclosure F01 PSU E2 (right)     Yellow
E22-J2 F02-E2 Storage enclosure F02 PSU E2 (right)     Yellow
E22-J3 F03-E2 Storage enclosure F03 PSU E2 (right)     Yellow
E22-J4 F04-E2 Storage enclosure F04 PSU E2 (right)     Yellow
E22-J5 F05-E2 Storage enclosure F05 PSU E2 (right)     Yellow
E22-J6 F06-E2 Storage enclosure F06 PSU E2 (right)     Yellow
PDU E22 (lower half)
E22-J7   Not used     Yellow
E22-J8   Not used     Yellow
E22-J9   Not used     Yellow
E22-J10   Not used     Yellow
E22-J11 F07-E2 Storage enclosure F07 PSU E2 (right)     Yellow
E22-J12 F08-E2 Storage enclosure F08 PSU E2 (right)     Yellow
PDU E23 (upper half)
E23-J1   Not used     Green
E23-J2   Not used     Green
E23-J3 XI1-E2 Front upper right I/O, power supply E2 (right)     Green
E23-J4 XI2-E2 Front upper left I/O, power supply E2 (right)     Green
E23-J5 XC1-E1 Upper CEC, power supply E1 (left)     Green
E23-J6 XC1-E2 Upper CEC, power supply E2     Green
PDU E23 (lower half)
E23-J7   Not used     Green
E23-J8   Not used     Green
E23-J9 XI3-E2 Front lower right I/O, power supply E2 (right)     Green
E23-J10 XI4-E2 Front lower left I/O, power supply E2 (right)     Green
E23-J11 XC2-E1 Lower CEC, power supply E1 (left)     Green
E23-J12 XC2-E2 Lower CEC, power supply E2     Green
PDU E24 (upper half)
E24-J1   Not used     Yellow
E24-J2   Not used     Yellow
E24-J3 XI1-E1 Front upper right I/O, power supply E1 (left)     Yellow
E24-J4 XI2-E1 Front upper left I/O, power supply E1 (left)     Yellow
E24-J5 XC1-E3 Upper CEC, power supply E3     Yellow
E24-J6 XC1-E4 Upper CEC, power supply E4 (right)     Yellow
PDU E24 (lower half)
E24-J7   Not used     Yellow
E24-J8   Not used     Yellow
E24-J9 XI3-E1 Front lower right I/O, power supply E1 (left)     Yellow
E24-J10 XI4-E1 Front lower left I/O, power supply E1 (left)     Yellow
E24-J11 XC2-E3 Lower CEC, power supply E3     Yellow
E24-J12 XC2-E4 Lower CEC, power supply E4 (right)     Yellow
Table 5. PDU-to-I/O and storage enclosure cabling - Rack 2 (Models 988, 88E)
PDU port Connects to Connection description P/N FRU/PN PDU group
PDU E21 (upper half)
E21-J1 F05-E1 Storage enclosure F05 PSU E1 (left)     Green
E21-J2 F06-E1 Storage enclosure F06 PSU E1 (left)     Green
E21-J3 F07-E1 Storage enclosure F07 PSU E1 (left)     Green
E21-J4 F08-E1 Storage enclosure F08 PSU E1 (left)     Green
E21-J5 F09-E1 Storage enclosure F09 PSU E1 (left)     Green
E21-J6 F01-E1 Storage enclosure F01 PSU E1 (left)     Green
PDU E21 (lower half)
E21-J7 F02-E1 Storage enclosure F02 PSU E1 (left)     Green
E21-J8 F03-E1 Storage enclosure F03 PSU E1 (left)     Green
E21-J9 F04-E1 Storage enclosure F04 PSU E1 (left)     Green
E21-J10 F10-E1 Storage enclosure F10 PSU E1 (left)     Green
E21-J11 F11-E1 Storage enclosure F11 PSU E1 (left)     Green
E21-J12 F12-E1 Storage enclosure F12 PSU E1 (left)     Green
PDU E22 (upper half)
E22-J1 F05-E2 Storage enclosure F05 PSU E2 (right)     Yellow
E22-J2 F06-E2 Storage enclosure F06 PSU E2 (right)     Yellow
E22-J3 F07-E2 Storage enclosure F07 PSU E2 (right)     Yellow
E22-J4 F08-E2 Storage enclosure F08 PSU E2 (right)     Yellow
E22-J5 F09-E2 Storage enclosure F09 PSU E2 (right)     Yellow
E22-J6 F01-E2 Storage enclosure F01 PSU E2 (right)     Yellow
PDU E22 (lower half)
E22-J7 F02-E2 Storage enclosure F02 PSU E2 (right)     Yellow
E22-J8 F03-E2 Storage enclosure F03 PSU E2 (right)     Yellow
E22-J9 F04-E2 Storage enclosure F04 PSU E2 (right)     Yellow
E22-J10 F10-E2 Storage enclosure F10 PSU E2 (right)     Yellow
E22-J11 F11-E2 Storage enclosure F11 PSU E2 (right)     Yellow
E22-J12 F12-E2 Storage enclosure F12 PSU E2 (right)     Yellow
PDU E23 (upper half)
E23-J1   Not used     Green
E23-J2   Not used     Green
E23-J3   Not used     Green
E23-J4   Not used     Green
E23-J5   Not used     Green
E23-J6 XI1-E2 Front upper right I/O, power supply E2 (right)     Green
PDU E23 (lower half)
E23-J7   Not used     Green
E23-J8   Not used     Green
E23-J9   Not used     Green
E23-J10 XI2-E2 Front upper left I/O, power supply E2 (right)     Green
E23-J11 XI3-E2 Front lower right I/O, power supply E2 (right)     Green
E23-J12 XI4-E2 Front lower left I/O, power supply E2 (right)     Green
PDU E24 (upper half)
E24-J1   Not used     Yellow
E24-J2   Not used     Yellow
E24-J3   Not used     Yellow
E24-J4   Not used     Yellow
E24-J5   Not used     Yellow
E24-J6 XI1-E1 Front upper right I/O, power supply E1 (left)     Yellow
PDU E24 (lower half)
E24-J7   Not used     Yellow
E24-J8   Not used     Yellow
E24-J9   Not used     Yellow
E24-J10 XI2-E1 Front upper left I/O, power supply E1 (left)     Yellow
E24-J11 XI3-E1 Front lower right I/O, power supply E1 (left)     Yellow
E24-J12 XI4-E1 Front lower left I/O, power supply E1 (left)     Yellow
Table 6. PDU-to-storage enclosure cabling - Rack 3 (Models 988, 88E)
PDU port Connects to Connection description P/N FRU/PN PDU group
Note: For further guidance on the connects to locations in this table, refer to:
PDU E21 (upper half)
E21-J1   Not used     Green
E21-J2   Not used     Green
E21-J3 F01-E1 Storage enclosure F01 PSU E1 (left)     Green
E21-J4 F02-E1 Storage enclosure F02 PSU E1 (left)     Green
E21-J5 F03-E1 Storage enclosure F03 PSU E1 (left)     Green
E21-J6 F04-E1 Storage enclosure F04 PSU E1 (left)     Green
PDU E21 (lower half)
E21-J7   Not used     Green
E21-J8   Not used     Green
E21-J9   Not used     Green
E21-J10   Not used     Green
E21-J11   Not used     Green
E21-J12   Not used     Green
PDU E22 (upper half)
E22-J1   Not used     Yellow
E22-J2   Not used     Yellow
E22-J3 F01-E2 Storage enclosure F01 PSU E2 (right)     Yellow
E22-J4 F02-E2 Storage enclosure F02 PSU E2 (right)     Yellow
E22-J5 F03-E2 Storage enclosure F03 PSU E2 (right)     Yellow
E22-J6 F04-E2 Storage enclosure F04 PSU E2 (right)     Yellow
PDU E22 (lower half)
E22-J7   Not used     Yellow
E22-J8   Not used     Yellow
E22-J9   Not used     Yellow
E22-J10   Not used     Yellow
E22-J11   Not used     Yellow
E22-J12   Not used     Yellow
PDU E23 (upper half)
E23-J1 F05-E1 Storage enclosure F05 PSU E1 (left)     Green
E23-J2 F06-E1 Storage enclosure F06 PSU E1 (left)     Green
E23-J3 F07-E1 Storage enclosure F07 PSU E1 (left)     Green
E23-J4 F08-E1 Storage enclosure F08 PSU E1 (left)     Green
E23-J5   Not used     Green
E23-J6   Not used     Green
PDU E23 (lower half)
E23-J7 F09-E1 Storage enclosure F09 PSU E1 (left)     Green
E23-J8 F10-E1 Storage enclosure F10 PSU E1 (left)     Green
E23-J9 F11-E1 Storage enclosure F11 PSU E1 (left)     Green
E23-J10 F12-E1 Storage enclosure F12 PSU E1 (left)     Green
E23-J11   Not used     Green
E23-J12   Not used     Green
PDU E24 (upper half)
E24-J1 F05-E2 Storage enclosure F05 PSU E2 (right)     Yellow
E24-J2 F06-E2 Storage enclosure F06 PSU E2 (right)     Yellow
E24-J3 F07-E2 Storage enclosure F07 PSU E2 (right)     Yellow
E24-J4 F08-E2 Storage enclosure F08 PSU E2 (right)     Yellow
E24-J5   Not used     Yellow
E24-J6   Not used     Yellow
PDU E24 (lower half)
E24-J7 F09-E2 Storage enclosure F09 PSU E2 (right)     Yellow
E24-J8 F10-E2 Storage enclosure F10 PSU E2 (right)     Yellow
E24-J9 F11-E2 Storage enclosure F11 PSU E2 (right)     Yellow
E24-J10 F12-E2 Storage enclosure F12 PSU E2 (right)     Yellow
E24-J11   Not used     Yellow
E24-J12   Not used     Yellow
Table 7. Power junction assembly (PJA) cabling, PJA E41 (Models 984, 985, 986, 988)
PJA port label PDU port Connects to Connection description P/N FRU P/N Power source
MINI PC_1 E41-J1 HMC1 Y cable to HMC1   R1-XI4
MINI PC_2 E41-J2 HMC2 Y cable to HMC2     R1-XI4
12V IN E41-J4 R1-XI4-P1-C7-T10 Y cable from I/O enclosure R1-XI4     R1-XI4
E-SWITCH_1 E41-J5 SW1 Y cable to Ethernet SW1 (black)     R1-XI4
E-SWITCH_2 E41-J7 SW2 Y cable to Ethernet SW2 (gray)     R1-XI4
MONITOR E41-J9 Monitor Y cable to HMC monitor     R1-XI4
Note: PJA input cable is shared with PJA E52.
Table 8. Power junction assembly (PJA) cabling, PJA E42 (Models 984, 985, 986, 988)
PJA port label PDU port Connects to Connection description P/N FRU P/N Power source
MINI PC_1 E42-J1 HMC1 Y cable to HMC1   R1-XI3
MINI PC_2 E42-J2 HMC2 Y cable to HMC2     R1-XI3
12V IN E42-J4 R1-XI3-P1-C7-T10 Y cable from I/O enclosure R1-XI3     R1-XI3
E-SWITCH_1 E42-J5 SW1 Y cable to Ethernet SW1 (black)     R1-XI3
E-SWITCH_2 E42-J7 SW2 Y cable to Ethernet SW2 (gray)     R1-XI3
MONITOR E42-J9 Monitor Y cable to HMC monitor     R1-XI3
Note: PJA input cable is shared with PJA E51 (if present).
Table 9. Power junction assembly (PJA) cabling, PJA E51, E53 (Models 988, 88E Rack-1)
PJA port label PJA port Connects to Connection description P/N FRU P/N Power source
12V IN R1-E51-J10 R1-XI3-P1-C7-T10 Y cable from I/O enclosure R1-XI3   R1-XI3
MICROBAY_1 R1-E51-J11 R1-M08-C1-T6 Microbay M08-C1 (left)     R1-XI3
MICROBAY_2 R1-E51-J12 R1-M04-C2-T6 Microbay M04-C2 (right)     R1-XI3
12V IN R1-E53-J10 R1-XI1-P1-C7-T10 I/O enclosure R1-XI1     R1-XI1
MICROBAY_1 R1-E53-J11 R1-M06-C1-T6 Microbay M06-C1 (left)     R1-XI1
MICROBAY_2 R1-E53-J12 R1-M02-C2-T6 Microbay M02-C2 (right)     R1-XI1
Note: In Rack-1, PJA E51 input cable is a Y cable that is shared with PJA E42.
Table 10. Power junction assembly (PJA) cabling, PJA E52, E54 (Models 988, 88E Rack-1)
PJA port label PJA port Connects to Connection description P/N FRU P/N Power source
12V IN R1-E52-J10 R1-XI4-P1-C7-T10 Y cable from I/O enclosure R1-XI4   R1-XI4
MICROBAY_1 R1-E52-J11 R1-M08-C2-T6 Microbay M08-C2 (right)     R1-XI4
MICROBAY_2 R1-E52-J12 R1-M04-C1-T6 Microbay M04-C1 (left)     R1-XI4
12V IN R1-E54-J10 R1-XI2-P1-C7-T10 I/O enclosure R1-XI2     R1-XI2
MICROBAY_1 R1-E54-J11 R1-M06-C2-T6 Microbay M06-C2 (right)     R1-XI2
MICROBAY_2 R1-E54-J12 R1-M02-C1-T6 Microbay M02-C1 (left)     R1-XI2
Note: In Rack-1, PJA E52 input cable is a Y cable that is shared with PJA E41.
Table 11. Power junction assembly (PJA) cabling, PJA E51, E53 (Models 988, 88E Rack-2)
PJA port label PJA port Connects to Connection description P/N FRU P/N Power source
12V IN R2-E51-J10 R2-XI3-P1-C7-T10 I/O enclosure R2-XI3   R2-XI3
MICROBAY_1 R2-E51-J11 R2-M12-C1-T6 Microbay M12-C1 (left)     R2-XI3
MICROBAY_2 R2-E51-J12 R2-M08-C2-T6 Microbay M08-C2 (right)     R2-XI3
12V IN R2-E53-J10 R2-XI1-P1-C7-T10 I/O enclosure R2-XI1     R2-XI1
MICROBAY_1 R2-E53-J11 R2-M10-C1-T6 Microbay M10-C1 (left)     R2-XI1
MICROBAY_2 R2-E53-J12 R2-M06-C2-T6 Microbay M06-C2 (right)     R2-XI1
Table 12. Power junction assembly (PJA) cabling, PJA E52, E54 (Models 988, 88E Rack-2)
PJA port label PJA port Connects to Connection description P/N FRU P/N Power source
12V IN R2-E52-J10 R2-XI4-P1-C7-T10 I/O enclosure R2-XI4   R2-XI4
MICROBAY_1 R2-E52-J11 R2-M12-C2-T6 Microbay M12-C2 (right)     R2-XI4
MICROBAY_2 R2-E52-J12 R2-M08-C1-T6 Microbay M08-C1 (left)     R2-XI4
12V IN R2-E54-J10 R2-XI2-P1-C7-T10 I/O enclosure R2-XI2     R2-XI2
MICROBAY_1 R2-E54-J11 R2-M10-C2-T6 Microbay M10-C2 (right)     R2-XI2
MICROBAY_2 R2-E54-J12 R2-M06-C1-T6 Microbay M06-C1 (left)     R2-XI2