SRNs 101-000 through 59D-xxx
This section lists the SRNs 101-000 through 59D-xxx.
| Service Request Number | Failing Function Codes | Description/Action |
|---|---|---|
| 101-000 | The system hung while attempting to configure a device. Action: Use PFW1540. |
|
| 101-185 | A checkstop occurred. Action: Use PFW1540. |
|
| 101-517 | The system unit failed to IPL. Action: Use PFW1540. |
|
| 101-518 | CD-ROM read problems after boot.
Note: The boot record was read from the CD-ROM disk. However,
errors occurred when trying to mount the CD-ROM file system. This problem can be caused by SCSI
device addressing, SCSI terminator, open PTC, SCSI cable, etc.
Note: Action: Go to MAP0050 SCSI bus problems.
|
|
| 101-521 to 101-538 | The configuration manager detected an error. Action: If you are running the diagnostics from a disk, try running standalone diagnostics. If standalone diagnostics run correctly, the problem might be damaged data on the disk. Contact your software support facility. If a different problem occurs when you run standalone diagnostics, correct that problem. If you were running standalone at first, have the same problem running standalone diagnostics that you had when running diagnostics from disk, or these actions did not resolve the problem, go PFW1540. |
|
| 101-544 | Disk read problems occurred after booting. Note: The boot record was read from
the disk. However, errors occurred when trying to open the disk drive. This problem can be caused by
SCSI device addressing, SCSI terminator, open PTC, SCSI cable, etc.
Action: Go to MAP0050 SCSI bus problems. |
|
| 101-551 to 101-557 | The system hung while loading the software. This can be caused by a hardware
or software problem. Action: Run the standalone diagnostics. If the standalone diagnostics run correctly, the problem might be a damaged disk data. Consider having the customer contact Software Support before reinstalling the operating system on the disk. Otherwise, go to MAP0020 Problem determination procedure. If a different problem occurs when you run the standalone diagnostics, correct that problem. If the standalone diagnostics still produces the same SRN, go to PFW1540. |
|
| 101-558 | There is not enough memory to execute diagnostics. Action: There must be a minimum of 16 MB of installed memory. If the system has 16 MB or more of memory installed, suspect a problem with a memory card. |
|
| 101-559 to 101-599 | The system halted while software was loading. This problem
might be attributed to either hardware or software. Action: Use the standalone diagnostics if not yet used. If the same SRN is generated from standalone diagnostics, go to PFW1540 for problem isolation. If a different problem occurs when you run the standalone diagnostics, correct that problem. If the SRN is not generated running standalone diagnostics, suspect a problem with the system's software. |
|
| 101-662 | An unexpected system interrupt. Action: Use PFW1540. | |
| 101-711 to 101-726 | xxx | The system hung while trying to configure an unknown resource. Action: Run standalone diagnostics. Start at MAP0020 Problem determination procedure, step 14. If you still get the same SRN, refer to Failing function code list and find the FFC that matches the last three digits of the SRN. Suspect the device adapter or device itself. If more than one adapter or device is installed, isolate the failing resource by removing the adapters or devices one at a time and checking if the system stops with the same value in the three-digit display. Note: xxx
corresponds to the last three digits of the SRN.
|
| 101-727 | The system hung while trying to configure an asynchronous
adapter. Action: Use PFW1540. Suspect a problem with one of the async adapters. |
|
| 101-7C1 | 7C1 | The system unit halted while configuring an audio
subsystem. Action: Go to MAP0210 General problem resolution. |
| 101-80c | 80c | A potential problem with an SSA device exists. The DS8000® series does not use SSA adapters. Call the next level of support. |
| 101-840 | An unexpected system interrupt. Action: Use PFW1540. Suspect either a SCSI adapter or integrated SCSI if so equipped. |
|
| 101-888 | 210
227 E10 |
The system does not IPL. Action: Go to MAP0210 General problem resolution. |
| 101-c32 | The system hung while indicating that a direct-attached display was selected
as the console. Action: Use PFW1540. Suspect the graphics adapter being used for the display console first. |
|
| 101-c33 | The system hung while indicating that a TTY terminal is the system console.
Action: Use PFW1540. Suspect the graphics adapter being used for the display console first. |
|
| 101-c70 | A problem was encountered mounting the CD-ROM. Action: Use PFW1540. |
|
| 101-2004 | Maximum memory size of partition is too large with respect
to the current partition memory size. Action: Specify a maximum memory size for the partition no larger than 64 times the starting memory size of the partition. |
|
| 101-xxxx | xxxx
E10 |
The system hung while configuring a resource. The last three or four digits
after the dash (-) identify the failing function code for the resource being configured. Action: Go to MAP0260 System hangs during resource configuration. |
| 103-151 | 151 | The time-of-day battery failed. Action: Go to MAP0210 General problem resolution. |
| 109-200 | The system crashed while being run by the customer. Action: Use MAP0020 Problem determination procedure, and get a new SRN. |
|
| 110-101 | The diagnostics did not detect an installed resource. Action: If this SRN appeared when running concurrent diagnostics, and then run concurrent using the diag -a command, otherwise use MAP0290 Missing Resource Problem Resolution. |
|
| 110-908 | 908
C33 C36 |
The system halted while diagnostics were executing. Action: Go to MAP0210 General problem resolution. |
| 110-921 to 110-926 | xxx
812 |
The system halted while diagnostics were executing. Note: xxx
corresponds to the last three digits of the SRN.
Action: Go to MAP0210 General problem resolution. |
| 110-935 | 935
812 |
The system halted while diagnostics were executing. Action: Go to MAP0210 General problem resolution. |
| 110-946 | 946
221 |
The system halted while diagnostics were executing. Action: Go to MAP0210 General problem resolution. |
| 110-xxxx | xxxx
221 |
The system halted while diagnostics were executing. Note: xxxx
corresponds to the last three or four digits of the SRN following the dash (-). If your 110 SRN is
not listed, substitute the last three or four digits of the SRN for xxxx, and then proceed to
the FFC table using the substituted digits as your
FFC.
Action: Go to MAP0210 General problem resolution. |
| 111-107 | A machine check occurred. Action: Go to MAP0020 Problem determination procedure. |
|
| 111-108 | An encoded SRN was displayed. Action: Go to MAP0020 Problem determination procedure. |
|
| 111-121 | There is a display problem. Action: Do problem determination on the
display. Action: Go to MAP0210 General problem resolution. |
|
| 111-259 | Cannot display readable information on the terminal. Action: Go to MAP0280 Console and Keyboard Problem Resolution Entry 3. |
|
| 111-725 | 725 | Cannot display readable information on the display. Note: Suspect the display
adapter attached to the console display.
Action: Go to MAP0280 Console and Keyboard Problem Resolution. |
| 111-736 | 736
821 |
The keyboard does not respond. Action: Go to MAP0280 Console and Keyboard Problem Resolution Entry 1. |
| 111-78C | PCI adapter
227 E10 |
I/O bus problem.
Action: Go to MAP0210 General problem resolution Note: PCI adapter refers to the adapters you made note of when using MAP0280 Console and Keyboard Problem Resolution.
|
| 111-82C | Cannot display readable information on the display. Action: Go to MAP0280 Console and Keyboard Problem Resolution, Entry 2. |
|
| 111-921 | 921
821 |
The keyboard does not respond. Action: Go to MAP0280 Console and Keyboard Problem Resolution, Entry 1. |
| 111-922 | 921
821 |
The keyboard does not respond. Action: Go to MAP0280 Console and Keyboard Problem Resolution, Entry 1. |
| 111-923 | 923
821 |
The keyboard does not respond. Action: Go to MAP0280 Console and Keyboard Problem Resolution, Entry 1. |
| 111-947 | 221 | System beeper not functioning correctly. Action: Go to MAP0210 General problem resolution. |
| 111-999 | 210 | System does not perform a soft reset. Action: Go to MAP0210 General problem resolution. |
| 199-102 | 199 | A critical failure has occurred on an undefined element. Action: Go to MAP2010 RPC card causes false fence. |
| 199-103 | 199 | Non-critical failure has occurred on an undefined element. Action: Go to MAP2010 RPC card causes false fence. |
| 199-104 | 199 | An unrecoverable failure has occurred on an undefined element. Action: Go to MAP2010 RPC card causes false fence. |
| 199-122 | 152 | A critical power supply failure has occurred. Action: Go to MAP2010 RPC card causes false fence. |
| 199-123 | 152 | A non-critical power supply failure has occurred. Action: Go to MAP2010 RPC card causes false fence. |
| 199-124 | 152 | An unrecoverable power supply failure has occurred. Action: Go to MAP2010 RPC card causes false fence. |
| 199-132 | 166
199 |
A critical fan failure has occurred. Action: Go to MAP2010 RPC card causes false fence. |
| 199-133 | 166
199 |
A non-critical fan failure has occurred. Action: Go to MAP2010 RPC card causes false fence. |
| 199-134 | 166
199 |
An unrecoverable fan failure has occurred. Action: Go to MAP2010 RPC card causes false fence. |
| 199-148 | 166
199 |
The enclosure indicates a temperature threshold warning. Action: Go to MAP2010 RPC card causes false fence. |
| 199-149 | 166
199 |
The enclosure indicates a temperature threshold failure. Action: Go to MAP2010 RPC card causes false fence. |
| 199-152 | 199 | A critical repeater card failure has occurred. Action: Go to MAP2010 RPC card causes false fence. |
| 199-153 | 199 | A non-critical repeater card failure has occurred. Action: Go to MAP2010 RPC card causes false fence. |
| 199-154 | 199 | An unrecoverable repeater card failure has occurred. Action: Go to MAP2010 RPC card causes false fence. |
| 199-162 | 199 | A critical VPD module failure has occurred. Action: Go to MAP2010 RPC card causes false fence. |
| 199-163 | 199 | A non-critical VPD module failure has occurred. Action: Go to MAP2010 RPC card causes false fence. |
| 199-164 | 199 | An unrecoverable VPD module failure has occurred. Action: Go to MAP2010 RPC card causes false fence. |
| 199-172 | 199 | A critical enclosure services failure has occurred. Action: Go to MAP2010 RPC card causes false fence. |
| 199-173 | 199 | A non-critical enclosure services failure has occurred. Action: Go to MAP2010 RPC card causes false fence. |
| 199-174 | 199 | An unrecoverable enclosure services failure has occurred. Action: Go to MAP2010 RPC card causes false fence. |
| 199-182 | 199 | A critical failure has occurred on a user defined element. Action: Go to MAP2010 RPC card causes false fence. |
| 199-183 | 199 | A non-critical failure has occurred on a user defined element. Action: Go to MAP2010 RPC card causes false fence. |
| 199-184 | 199 | An unrecoverable failure has occurred on a user defined element. Action: Go to MAP2010 RPC card causes false fence. |
| 199-192 | 199 | A critical failure has occurred on a user defined element. Action: Go to MAP2010 RPC card causes false fence. |
| 199-193 | 199 | A non-critical failure has occurred on a user defined element. Action: Go to MAP2010 RPC card causes false fence. |
| 199-194 | 199 | An unrecoverable failure has occurred on a user defined element. Action: Go to MAP2010 RPC card causes false fence. |
| 199-201 | 199
891 |
Device configuration error. Action: Go to MAP2010 RPC card causes false fence. |
| 199-202 | 199
891 |
The enclosure failed to open. Action: Go to MAP2010 RPC card causes false fence. |
| 199-203 | 199
891 |
The enclosure failed to return inquiry data. Action: Go to MAP2010 RPC card causes false fence. |
| 199-204 | 152
166 |
There is a critical power supply or fan failure. Action: Go to MAP2010 RPC card causes false fence. |
| 199-205 | 152
166 |
There is a redundant power supply or fan failure. Action: Go to MAP2010 RPC card causes false fence. |
| 2E6-101 | 221 | Enhanced error handling failure on the bus. Action: Go to MAP0210 General problem resolution. |
| 2E6-102 | 293 | Enhanced error handling failure on a PCI-PCI Bridge. Action: Go to MAP0210 General problem resolution. |
| 2E6-103 | 2E6
221 |
Enhanced error handling failure on the adapter. Action: Go to MAP0210 General problem resolution. |
| 2E6-212 | 2E6 | FIFO empty bit set. Action: Go to MAP0210 General problem resolution. |
| 2E6-213 | 2E6 | FIFO empty bit clear. Action: Go to MAP0210 General problem resolution. |
| 2E6-214 | 2E6 | FIFO full bit set. Action: Go to MAP0210 General problem resolution. |
| 2E6-215 | 2E6 | FIFO full bit clear. Action: Go to MAP0210 General problem resolution. |
| 2E6-216 | 2E6 | FIFO data miscompare. Action: Go to MAP0210 General problem resolution. |
| 2E6-217 | 2E6 | SCSI FIFO data miscompare. Action: Go to MAP0210 General problem resolution. |
| 2E6-218 | 2E6 | SCSI FIFO underflow. Action: Go to MAP0210 General problem resolution. |
| 2E6-219 | 2E6 | SCSI parity error. Action: Go to MAP0050 SCSI bus problems. |
| 2E6-220 | 2E6 | SCSI FIFO flags error. Action: Go to MAP0210 General problem resolution. |
| 2E6-221 | 2E6
221 |
Miscompare during the write/read of the configuration register. Action: Go to MAP0210 General problem resolution. |
| 2E6-222 | 2E6 | Error during the write/read of the memory register. Action: Go to MAP0210 General problem resolution. |
| 2E6-223 | 2E6 | Miscompare during the write/read of the memory I/O register. Action: Go to MAP0050 SCSI bus problems. |
| 2E6-224 | 2E6
221 |
SCSI configuration register read or write error. Action: Go to MAP0210 General problem resolution. |
| 2E6-225 | 2E6 | Adapter POST failed. Action: Go to MAP0210 General problem resolution. |
| 2E6-226 | SCSI wrap or PTC failure. Action: Go to MAP0050 SCSI bus problems. |
|
| 2E6-227 | 2E6
221 |
SCSI adapter test failure. Action: Go to MAP0210 General problem resolution. |
| 2E6-230 | Arbitration test failed. Action: Go to MAP0050 SCSI bus problems. |
|
| 2E6-231 | 2E6
221 |
Function could not complete. Action: Go to MAP0050 SCSI bus problems. |
| 2E6-232 | SCSI bus data miscompare. Action: Go to MAP0050 SCSI bus problems. |
|
| 2E6-240 | No terminal power. Action: Go to MAP0050 SCSI bus problems. |
|
| 2E6-242 | SCSI bus problem. Action: Go to MAP0050 SCSI bus problems. |
|
| 2E6-301 | 2E6
221 |
The parent device open failed. Action: Go to MAP0210 General problem resolution. |
| 2E6-701 | 2E6 | Error log analysis indicates a PCI SCSI adapter failure. Action: Go to MAP0210 General problem resolution. |
| 2E6-801 | Error log analysis indicates a terminator problem. Action: Run the diagnostics on the adapter in system verification mode. If an SRN is reported, use the SRN to resolve the problem. If an SRN is not reported, use the SCSI service hints in General SCSI Configuration Checks to resolve the problem. |
|
| 2E6-802 | Error log analysis indicates that multiple attempts to reset the SCSI bus have
timed out. Action: Run the diagnostics on the adapter in system verification mode. If an SRN is reported, use the SRN to resolve the problem. If an SRN is not reported, use the SCSI service hints inGeneral SCSI Configuration Checks to resolve the problem. |
|
| 2E6-803 | Error log analysis indicates that multiple SCSI bus errors have occurred.
Action: Run the diagnostics on the adapter in system verification mode. If an SRN is reported, use the SRN to resolve the problem. If an SRN is not reported, use the SCSI service hints in General SCSI Configuration Checks to resolve the problem. |
|
| 2E7-101 | 221 | Enhanced error handling failure on the bus. Action: Go to MAP0210 General problem resolution. |
| 2E7-102 | 293 | Enhanced error handling failure on a PCI-PCI Bridge. Action: Go to MAP0210 General problem resolution. |
| 2E7-103 | 2E7
221 |
Enhanced error handling failure on the adapter. Action: Go to MAP0210 General problem resolution. |
| 2E7-212 | 2E7 | FIFO empty bit set. Action: Go to MAP0210 General problem resolution. |
| 2E7-213 | 2E7 | FIFO empty bit clear. Action: Go to MAP0210 General problem resolution. |
| 2E7-214 | 2E7 | FIFO full bit set. Action: Go to MAP0210 General problem resolution. |
| 2E7-215 | 2E7 | FIFO full bit clear. Action: Go to MAP0210 General problem resolution. |
| 2E7-216 | 2E7 | FIFO data miscompare. Action: Go to MAP0210 General problem resolution. |
| 2E7-217 | 2E7 | SCSI FIFO data miscompare. Action: Go to MAP0210 General problem resolution. |
| 2E7-218 | 2E7 | SCSI FIFO underflow. Action: Go to MAP0210 General problem resolution. |
| 2E7-219 | SCSI parity error. Action: Action: Go to MAP0050 SCSI bus problems. |
|
| 2E7-220 | 2E7 | SCSI FIFO flags error. Action: Go to MAP0210 General problem resolution. |
| 2E7-221 | 2E7
221 |
Miscompare during the write/read of the configuration register. Action: Go to MAP0210 General problem resolution. |
| 2E7-222 | 2E7 | Error during the write/read of the memory register. Action: Go to MAP0210 General problem resolution. |
| 2E7-223 | 2E7 | Miscompare during the write/read of the memory I/O register. Action: Go to MAP0050 SCSI bus problems. |
| 2E7-224 | 2E7
221 |
SCSI configuration register read or write error. Action: Go to MAP0210 General problem resolution. |
| 2E7-225 | 2E7 | Adapter POST failed. Action: Go to MAP0210 General problem resolution. |
| 2E7-226 | SCSI wrap or PTC failure. Action: Go to MAP0050 SCSI bus problems. |
|
| 2E7-227 | 2E7
221 |
SCSI adapter test failure. Action: Go to MAP0210 General problem resolution. |
| 2E7-230 | Arbitration test failed. Action: Go to MAP0050 SCSI bus problems. |
|
| 2E7-231 | Function could not complete. Action: Go to MAP0050 SCSI bus problems. |
|
| 2E7-232 | SCSI bus data miscompare. Action: Go to MAP0050 SCSI bus problems. |
|
| 2E7-240 | No terminal power. Action: Go to MAP0050 SCSI bus problems. |
|
| 2E7-242 | SCSI bus problem. Action: Go to MAP0050 SCSI bus problems. |
|
| 2E7-301 | 2E7 | Configuration open failed for parent bus. Action: Go to MAP0210 General problem resolution. |
| 2E7-701 | 2E7 | Error log analysis indicates a PCI SCSI adapter failure. Action: Go to MAP0210 General problem resolution. |
| 2E7-801 | Error log analysis indicates a terminator problem. Action: Run the diagnostics on the adapter in system verification mode. If an SRN is reported, use the SRN to resolve the problem. If an SRN is not reported, use the SCSI service hints in General SCSI Configuration Checks to resolve the problem. |
|
| 2E7-802 | Error log analysis indicates that multiple attempts
to reset the SCSI bus have timed out. Action: Run the diagnostics on the adapter in system verification mode. If an SRN is reported, use the SRN to resolve the problem. If an SRN is not reported, use the SCSI service hints in General SCSI Configuration Checks to resolve the problem. |
|
| 2E7-803 | Error log analysis indicates that multiple SCSI bus errors have occurred.
Action: Run the diagnostics on the adapter in system verification mode. If an SRN is reported, use the SRN to resolve the problem. If an SRN is not reported, use the SCSI service hints in General SCSI Configuration Checks to resolve the problem. |
|
| 2EF-101 | 751 | Post indicates an adapter failure. Action: Go to MAP0210 General problem resolution. |
| 440-xxx to 443-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 444-101 | 2C3
444 |
External wrap test failed on port 0. Action: Go to MAP0210 General problem resolution. |
| 444-102 | 2C3
444 |
External wrap test failed on port 1. Action: Go to MAP0210 General problem resolution. |
| 444-103 | 227 | Enhanced error handling failure on bus. Action: Go to MAP0210 General problem resolution. |
| 444-104 | 227 | Enhanced error handling failure on Eads chip. Action: Go to MAP0210 General problem resolution. |
| 444-105 | 444 | Enhanced error handling failure on adapter. Action: Go to MAP0210 General problem resolution. |
| 444-106 | 776
646 |
Enhanced error handling failure on bus. Action: Go to MAP0210 General problem resolution. |
| 444-107 | 776
646 |
EEH failure on Eads chip. Action: Go to MAP0210 General problem resolution. |
| 444-108 | 776
646 |
Enhanced error handling failure on adapter. Action: Go to MAP0210 General problem resolution. |
| 444-201 | 444
227 |
Internal adapter test failed. Action: Go to MAP0210 General problem resolution. |
| 444-202 | 444
227 |
External wrap test failed on port 0. Action: Go to MAP0210 General problem resolution. |
| 444-203 | 444
227 |
External wrap test failed on port 1. Action: Go to MAP0210 General problem resolution. |
| 444-204 | 2C3
444 |
External wrap test failed on port 0. Action: Go to MAP0210 General problem resolution. |
| 444-205 | 2C3
444 |
External wrap test failed on port 1. Action: Go to MAP0210 General problem resolution. |
| 444-206 | 2C3
444 software |
External wrap test failed on port 0. Action: Go to MAP0210 General problem resolution. |
| 444-207 | 2C3
444 software |
External wrap test failed on port 1. Action: Go to MAP0210 General problem resolution. |
| 444-208 | 444
227 |
Enhanced error handling failure opening the adapter. Action: Go to MAP0210 General problem resolution. |
| 444-301 | 444
227 software |
Internal adapter test failed. Action: Go to MAP0210 General problem resolution. |
| 444-302 | 444
227 software |
External wrap test failed on port 0. Action: Go to MAP0210 General problem resolution. |
| 444-303 | 444
227 software |
External wrap test failed on port 1. Action: Go to MAP0210 General problem resolution. |
| 444-304 | 2C3
444 software |
External wrap test failed on port 0. Action: Go to MAP0210 General problem resolution. |
| 444-305 | 2C3
444 software |
External wrap test failed on port 1. Action: Go to MAP0210 General problem resolution. |
| 444-700 | 444
software |
Error log analysis indicates a hardware problem. Action: Go to MAP0210 General problem resolution. |
| 444-701 | 444
227 |
Error log analysis indicates that this adapter has failed to initialize due to
enhanced error handling errors. Action: Go to MAP0210 General problem resolution. |
| 447-101 | 444 | The Fibre Channel Adapter configuration failed. Action: Go to MAP0210 General problem resolution. |
| 447-102 | 444 | The Reset test failed. Action: Go to MAP0210 General problem resolution. |
| 447-103 | 444 | The Register test failed. Action: Go to MAP0210 General problem resolution. |
| 447-104 | 444 | The SRAM test failed. Action: Go to MAP0210 General problem resolution. |
| 447-105 | 444 | The Internal Wrap test failed. Action: Go to MAP0210 General problem resolution. |
| 447-106 | 444 | Gigabaud Link Module (GLM) Wrap Test Failure. Action: Go to MAP0210 General problem resolution. |
| 447-107 | 444 | The External Wrap test failed. Action: Go to MAP0210 General problem resolution. |
| 447-109 | 221 | Enhanced Error Handling Failure on EADs chip. Action: Go to MAP0210 General problem resolution. |
| 447-110 | 444 | Enhanced Error Handling Failure on adapter. Action: Go to MAP0210 General problem resolution. |
| 447-201 | 447
221 |
The Configuration Register test failed. Action: Go to MAP0210 General problem resolution. |
| 447-202 | 447
221 |
The Interrupt test failed. Action: Go to MAP0210 General problem resolution. |
| 447-203 | 447
221 |
The PCI Wrap test failed. Action: Go to MAP0210 General problem resolution. |
| 447-204 | 447
221 |
The DMA test failed. Action: Go to MAP0210 General problem resolution. |
| 447-205 | 447
221 |
I/O error on a read/write operation. Action: Go to MAP0210 General problem resolution. |
| 447-701 | 447
221 |
Error log analysis indicates that an error has occurred
with the adapter. Action: Go to MAP0210 General problem resolution. |
| 447-703 | 447 | Error log analysis indicates that an unknown adapter
error has occurred. Action: Go to MAP0210 General problem resolution. |
| 447-704 | 447 | Error log analysis indicates that an adapter error has occurred. Action: Go to MAP0210 General problem resolution. |
| 447-705 | 447 | A parity error has been detected. The adapter must be
replaced immediately. Failure to do so could result in data being read or
written incorrectly. Action: Go to MAP0210 General problem resolution. |
| 447-706 | 447 | A fatal hardware error has occurred. This adapter was successfully taken offline. It will remain offline until reconfigured or the system is rebooted. This adapter must be replaced and not brought back online. Failure to adhere to this action could result in data being read or written incorrectly or in the loss of data. |
| 451-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 453-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 458-110 | 458 | The Reserve command failed. Action: Go to MAP0210 General problem resolution. |
| 458-120 | 458 | The Inquiry command failed. Action: Go to MAP0210 General problem resolution. |
| 458-130 | 458
media |
The Load command failed. Action: Go to MAP0210 General problem resolution. |
| 458-135 | 458
media |
The Unload command failed. Action: Go to MAP0210 General problem resolution. |
| 458-140 | 458 | The Mode Select command failed. Action: Go to MAP0210 General problem resolution. |
| 458-150 | 458
media |
The Test Unit Ready command failed. Action: Go to MAP0210 General problem resolution. |
| 458-160 | 458
media |
The Send Diagnostic command failed. Action: Go to MAP0210 General problem resolution. |
| 458-169 | 458
media |
The Send Diagnostic command failed. Action: Go to MAP0210 General problem resolution. |
| 458-170 | 458
B58 media |
The Read, Write and Compare test failed. Action: Go to MAP0210 General problem resolution. |
| 458-180 | 458
media |
The Load command failed. Action: Go to MAP0210 General problem resolution. |
| 458-185 | 458
media |
The Unload command failed. Action: Go to MAP0210 General problem resolution. |
| 458-190 | 458 | The Mode Select command failed. Action: Go to MAP0210 General problem resolution. |
| 458-200 | 458
media |
The Test Unit Ready command failed. Action: Go to MAP0210 General problem resolution. |
| 458-210 | 458
B88 |
The device configuration failed. Action: Go to MAP0210 General problem resolution. |
| 458-220 | 458 | The Release command failed. Action: Go to MAP0210 General problem resolution. |
| 458-230 | 458 | The Request Sense command failed. Action: Go to MAP0210 General problem resolution. |
| 458-240 | 458 | The Openx command failed. Action: Go to MAP0210 General problem resolution. |
| 458-300 | 458
software |
The device configuration failed. Action: Go to MAP0210 General problem resolution. |
| 458-310 | 458
B88 software |
SCSI adapter configuration failed. Action: Go to MAP0210 General problem resolution. |
| 458-320 | 458
media |
Error log analysis indicates a failure. Action: Go to MAP0210 General problem resolution. |
| 458-411 to 458-423 | 458
B88 software |
A reservation conflict occurred. Action: Go to MAP0210 General problem resolution. |
| 458-511 to 458-523 | 458
B88 |
The drive returned bad or non-extended sense data. Action: Go to MAP0210 General problem resolution. |
| 458-611 to 458-623 | 458
B88 software |
An adapter or bus I/O error occurred. Action: Go to MAP0210 General problem resolution. |
| 458-711 to 458-723 | 458
B88 software |
A device timeout error occurred. Action: Go to MAP0210 General problem resolution. |
| 459-110 | 459 | The Reserve command failed. Action: Go to MAP0210 General problem resolution. |
| 459-120 | 459 | The Inquiry command failed. Action: Go to MAP0210 General problem resolution. |
| 459-130 | 459
media |
The Load command failed. Action: Go to MAP0210 General problem resolution. |
| 459-135 | 459
media |
The Unload command failed. Action: Go to MAP0210 General problem resolution. |
| 459-140 | 459 | The Mode Select command failed. Action: Go to MAP0210 General problem resolution. |
| 459-150 | 459
media |
The Test Unit Ready command failed. Action: Go to MAP0210 General problem resolution. |
| 459-160 | 459
media |
The Send Diagnostic command failed. Action: Go to MAP0210 General problem resolution. |
| 459-169 | 459
media |
The Send Diagnostic command failed. Action: Go to MAP0210 General problem resolution. |
| 459-170 | 459
B88 media |
The Read, Write and Compare test failed. Action: Go to MAP0210 General problem resolution. |
| 459-180 | 459
media |
The Load command failed. Action: Go to MAP0210 General problem resolution. |
| 459-185 | 459
media |
The Unload command failed. Action: Go to MAP0210 General problem resolution. |
| 459-190 | 459 | The Mode Select command failed. Action: Go to MAP0210 General problem resolution. |
| 459-200 | 459
media |
The Test Unit Ready command failed. Action: Go to MAP0210 General problem resolution. |
| 459-210 | 459
B88 |
The device configuration failed. Action: Go to MAP0210 General problem resolution. |
| 459-220 | 459 | The Release command failed. Action: Go to MAP0210 General problem resolution. |
| 459-230 | 459 | The Request Sense command failed. Action: Go to MAP0210 General problem resolution. |
| 459-240 | 459 | The Openx command failed. Action: Go to MAP0210 General problem resolution. |
| 459-300 | 459
software |
The device configuration failed. Action: Go to MAP0210 General problem resolution. |
| 459-310 | B88
459 software |
SCSI adapter configuration failed. Action: Go to MAP0210 General problem resolution. |
| 459-320 | 459
media |
Error log analysis indicates a failure. Action: Go to MAP0210 General problem resolution. |
| 459-411 to 459-423 | 459
B88 media |
A reservation conflict occurred. Action: Go to MAP0210 General problem resolution. |
| 459-511 to 459-523 | 459
B88 |
The drive returned bad or non-extended sense data. Action: Go to MAP0210 General problem resolution. |
| 459-611 to 459-623 | 459
B88 software |
An adapter or bus I/O error occurred. Action: Go to MAP0210 General problem resolution. |
| 459-711 to 459-723 | 459
B88 software |
A device timeout error occurred. Action: Go to MAP0210 General problem resolution. |
| 541-xxx | 541 | A DLT tape device problem has occurred. Action: Refer to the DLT tape device documentation. |
| 542-xxx | 542 | An 8mm 60GB tape device problem has occurred. Action: Refer to the 8mm 60GB tape device documentation. |
| 56B-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 56D-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 57B-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 57D-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 58B-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 58D-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 59B-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). | |
| 59D-xxx | See SCSI Devices SRNs (ssss-102 to ssss-640). |